{"id":7847,"date":"2025-02-21T15:49:07","date_gmt":"2025-02-21T07:49:07","guid":{"rendered":"http:\/\/www.bio-oi.com\/?p=7847"},"modified":"2026-10-08T14:31:46","modified_gmt":"2026-10-08T06:31:46","slug":"multimodal-full-spectrum-in-vivo-imaging-system","status":"publish","type":"post","link":"https:\/\/www.bio-oi.com\/en\/2025\/02\/21\/multimodal-full-spectrum-in-vivo-imaging-system\/","title":{"rendered":"Multimodal Full-Spectrum In Vivo Imaging System"},"content":{"rendered":"<p style=\"text-align: justify;\">The LASER Series Multimodal Full-Spectrum In Vivo Imaging System is a newly developed plant and animal imaging system by BIO-OI \uff08GuangYi\uff09, featuring high resolution, high sensitivity, full-spectrum coverage, multifunctionality and wide applicability. The system combines research-grade deep-cooled cameras with high-definition InGaAs cameras to achieve full-spectrum imaging across 400-1700nm wave lengths, covering both visible light and NIR-II spectral ranges.<\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; color: #d9534f; font-size: 12pt;\"><strong>\u25a0 Product features<\/strong><\/span><\/p>\n<p><strong><span class=\"\">Dual-Camera Integration for Full-Spectrum Imaging Across the Wavelength Range<\/span><\/strong><\/p>\n<p style=\"text-align: justify;\">A research-grade deep-cooled camera for visible wavelengths, paired with a deep-cooled camera for the near-infrared II (NIR-II) region, enables full-spectrum imaging across the 400\u20131700 nm wavelength range.<\/p>\n<p><strong><span class=\"\">Professional Image Acquisition and Analysis Software<\/span><\/strong><\/p>\n<p style=\"text-align: justify;\">Our newly developed image acquisition and analysis software enables fully automated image data capture. It supports automatic overlay of fluorescence images with bright-field and X-ray images, with the added flexibility of manual post-overlay adjustment for refined analysis. The software performs spectral unmixing on acquired results; after unmixing, it automatically calculates grayscale values, photon counts, and ROI (region-of-interest) analysis. Additional advanced features include multi-image analysis, EDF (extended depth of field) fusion, and 3D data visualization.<\/p>\n<p><strong><span class=\"\">Multi-Source Illumination<\/span><\/strong><\/p>\n<p style=\"text-align: justify;\">LED visible light sources offer long life and excellent stability, while infrared laser sources are better suited for exciting deeper tissue layers. An optional X-ray source with adjustable intensity is also available for structural bone imaging, allowing visualization of skeletal, fat, and muscle information in animal models.<\/p>\n<p><strong><span class=\"\">Optional X-Ray Module<\/span><\/strong><span class=\"\"> (available as an add-on configuration)<\/span><\/p>\n<p><span style=\"font-size: 12pt; font-family: arial, helvetica, sans-serif;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7848 \" src=\"https:\/\/www.bio-oi.com\/wp-content\/uploads\/2025\/02\/\u5fae\u4fe1\u56fe\u7247_20250221150327-1024x266.png\" alt=\"\" width=\"669\" height=\"174\" srcset=\"https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5fae\u4fe1\u56fe\u7247_20250221150327-1024x266.png 1024w, https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5fae\u4fe1\u56fe\u7247_20250221150327-300x78.png 300w, https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5fae\u4fe1\u56fe\u7247_20250221150327-768x200.png 768w, https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5fae\u4fe1\u56fe\u7247_20250221150327-1536x399.png 1536w, https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5fae\u4fe1\u56fe\u7247_20250221150327.png 1727w\" sizes=\"auto, (max-width: 669px) 100vw, 669px\" \/><\/span><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">Tumor research, vascular imaging, drug development, targeted therapy, surgical navigation, gut microbiota imaging, lymphatic imaging, brain science, pharmacological research, drug efficacy evaluation, and pharmacokinetic studies of macromolecular drugs.<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-8180\" src=\"https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5168\u5149\u8c31\u5e94\u7528-1024x221.png\" alt=\"\" width=\"1024\" height=\"221\" srcset=\"https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5168\u5149\u8c31\u5e94\u7528-1024x221.png 1024w, https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5168\u5149\u8c31\u5e94\u7528-300x65.png 300w, https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5168\u5149\u8c31\u5e94\u7528-768x166.png 768w, https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5168\u5149\u8c31\u5e94\u7528-1536x332.png 1536w, https:\/\/www.bio-oi.com\/en\/wp-content\/uploads\/sites\/5\/2025\/02\/\u5168\u5149\u8c31\u5e94\u7528-2048x443.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The LASER Series Multimodal Full-Spectrum In Vivo Imaging System is a newly developed plant and animal imaging system by BIO-OI \uff08GuangYi\uff09, featuring high resolution, high sensitivity, full-spectrum coverage, multifunctionality and wide applicability. The system combines research-grade deep-cooled cameras with high-definition InGaAs cameras to achieve full-spectrum imaging across 400-1700nm wave lengths, covering both visible light and [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":7857,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[82],"tags":[],"class_list":["post-7847","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-living"],"_links":{"self":[{"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/posts\/7847","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/comments?post=7847"}],"version-history":[{"count":17,"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/posts\/7847\/revisions"}],"predecessor-version":[{"id":8182,"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/posts\/7847\/revisions\/8182"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/media\/7857"}],"wp:attachment":[{"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/media?parent=7847"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/categories?post=7847"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bio-oi.com\/en\/wp-json\/wp\/v2\/tags?post=7847"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}